KNX system products
Electrical Parameters
Bus Voltage: DC 21V ~ 30V (supplied via bus)
Bus Current: < 12 mA
Bus Power Consumption: < 360 mW
Input/Output
4/8/12 passive button channels
Each channel programmable as input or LED indicator
Temperature Range
Operating: -5℃ to +45℃
Storage: -25℃ to +55℃
Transport: -25℃ to +70℃
| Model | Product Dimensions | Modulus | Installation | Remark |
| DL-E/IUI04.1 | 43*43*11mm(L*W*H) | — | Flush-mounted junction box | — |
Electrical Parameters
Bus Voltage: DC 21V ~ 30V (supplied via bus)
Bus Current: < 12 mA
Bus Power Consumption: < 360 mW
Input/Output
4/8/12 passive button channels
Each channel programmable as input or LED indicator
Temperature Range
Operating: -5℃ to +45℃
Storage: -25℃ to +55℃
Transport: -25℃ to +70℃
| Model | Product Dimensions | Modulus | Installation | Remark |
| DL-E/IUI08.1 | 43*43*11mm(L*W*H) | — | Flush-mounted junction box | — |
Electrical Parameters
Bus Voltage: DC 21V ~ 30V (supplied via bus)
Bus Current: < 12 mA
Bus Power Consumption: < 360 mW
Input/Output
4/8/12 passive button channels
Each channel programmable as input or LED indicator
Temperature Range
Operating: -5℃ to +45℃
Storage: -25℃ to +55℃
Transport: -25℃ to +70℃
| Model | Product Dimensions | Modulus | Installation | Remark |
| DL-E/IUI12.1 | 43*43*11mm(L*W*H) | — | Flush-mounted junction box | — |
Bus Voltage: DC 21V ~ 30V, supplied via bus
Bus Current: < 12mA
Bus Power Consumption: < 360mW
Illuminance Detection Range: 0 ~ 65535 Lux
Motion Detection Radius: 4m
Temperature Range:
Operating: -5℃ ~ +45°C
Storage: -25℃ ~ +55°C
Transport: -25℃ ~ +70°C
| Model | Product Dimensions | Modulus | Installation | Remark |
| DL-E/IPB2.6.1 | 76*76*26.4mm(L*W*H) | — | Ceiling-mounted insallation | — |
Bus Voltage: DC 21V ~ 30V, supplied via bus
Bus Current: < 12mA
Bus Power Consumption: < 360mW
Illuminance Detection Range: 0 ~ 65535 Lux
Motion Detection Radius: 4m
Temperature Range:
Operating: -5℃ ~ +45°C
Storage: -25℃ ~ +55°C
Transport: -25℃ ~ +70°C
| Model | Product Dimensions | Modulus | Installation | Remark |
| DL-E/IDB3.8.1 | 86*86*35mm(L*W*H) | — | Ceiling-mounted insallation | — |
Bus Voltage: DC 21V ~ 30V, supplied via bus
Bus Current: < 12mA
Bus Power Consumption: < 360mW
Power Consumption: < 1.5W
Auxiliary Power Supply: DC 12V ~ 30V
Temperature Detection Range: -5℃ ~ +45℃
Humidity Detection Range: 0 ~ 100% RH
Temperature Detection Accuracy: ±1℃
Humidity Detection Accuracy: ±3% RH
PM2.5/10 Detection Range: 0 ~ 999 mg/m³
VOC Detection Range and Accuracy: 0 ~ 9.99 mg/m³
Temperature Range:
Operating: -5℃ ~ +45℃
Storage: -25℃ ~ +55℃
| Model | Product Dimensions | Modulus | Installation | Remark |
| DL-E/IAQ6.1 | 86*86*15.5mm(L*W*H) | — | Standard 86 Junction Box Mounting | With display screen |
| DL-E/IAQ6.5 | 86*86*15.5mm(L*W*H) | — | Standard 86 Junction Box Mounting | With display screen |
PM2.5 Monitoring with Bus Transmission and Logic Control
Bus Voltage: DC 21V ~ 30V, supplied via bus
Bus Current: < 12mA
Bus Power Consumption: < 360mW
Power Consumption: < 1.5W
Auxiliary Power Supply: DC 12V ~ 30V
PM2.5/10 Detection Range: 0 ~ 999 mg/m³
Temperature Range:
Operating: -5°C ~ +45℃
Storage: -25℃ ~ +55℃
| Model | Product Dimensions | Modulus | Installation | Remark |
| DL-E/IAQ6.2 | 86*86*15.5mm(L*W*H) | — | Standard 86 Junction Box Mounting | With display screen |
CO concentration monitoring with bus transmission and logic control
Bus Voltage: DC 21V-30V (supplied via bus)
Bus Current: < 12 mA
Bus Power Consumption: < 360 mW
Total Power Consumption: < 1.5 W
Auxiliary Power Supply: DC 12V-30V
CO Detection Range: 0-5000 ppm
CO Detection Accuracy: ±10 ppm
Temperature Range:
Operating: -5°C to +45°C
Storage: -25°C to +55°C
| Model | Product Dimensions | Modulus | Installation | Remark |
| DL-E/IAQ6.3 | 86*86*15.5mm(L*W*H) | — | Standard 86 Junction Box Mounting | With display screen |
CO₂ concentration monitoring with bus transmission and logic control
Bus Voltage: DC 21V-30V (supplied via bus)
Bus Current: < 12 mA
Bus Power Consumption: < 360 mW
Total Power Consumption: < 1.5 W
Auxiliary Power Supply: DC 12V-30V
CO₂ Detection Range: 400-2000 ppm
CO₂ Detection Accuracy: ±50 ppm
Temperature Range:
Operating: -5°C to +45°C
Storage: -25°C to +55°C
| Model | Product Dimensions | Modulus | Installation | Remark |
| DL-E/IAQ6.4 | 86*86*15.5mm(L*W*H) | — | Standard 86 Junction Box Mounting | With display screen |